ACOUSTIC SYSTEM DETAILS ● WIA APPROVED SYSTEM
← Back to results

Marksman

MMN44FAS004 · Operational test

29.00 dB Rw

Rw (C; Ctr) = 29.00 (-1; -1) dB

System specification

Door core
Marksman
Leaf thickness
44 mm
Doorset configuration
SADD
Glazing
Unglazed
Frame intumescent seal
15x4 Fire Only
Frame acoustic seal
Fire and Acoustic Seals FAS35
Meeting stile arrangement
1 No. 10x4 Fire Only, 1 No. 10x4 STS104SBS
Threshold seal
Fire & Acoustic Seals FAS45
Laboratory
Cambridge Acoustic Laboratory
Test report reference
24014-R01-A 
Test number
43
Index reference
MMN44FAS004

Acoustic performance

Measured sound reduction and ISO 717-1 shifted reference curve.

View frequency-band values
Frequency (Hz)Measured R (dB)
10022.2
12525.1
16026.2
20025.0
25027.1
31528.5
40029.9
50029.9
63030.3
80029.9
100027.4
125025.7
160026.5
200028.0
250028.8
315031.1

Published acoustic test evidence does not, by itself, establish fire-door compliance. Check the relevant fire test and application evidence for the intended installation.