ACOUSTIC SYSTEM DETAILS ● WIA APPROVED SYSTEM
← Back to results

Marksman

MMN44FAS007 · Operational test

31.00 dB Rw

Rw (C; Ctr) = 31.00 (-1; -2) dB

System specification

Door core
Marksman
Leaf thickness
44 mm
Doorset configuration
SADD
Glazing
Glazed - 7mm Glass
Frame intumescent seal
15x4 Fire Only
Frame acoustic seal
Fire and Acoustic Seals FAS35
Meeting stile arrangement
1 No. 10x4 Fire Only, 1 No. 10x4 Lorient DS
Threshold seal
Fire & Acoustic Seals FAS45
Laboratory
Cambridge Acoustic Laboratory
Test report reference
24014-R01-A 
Test number
48
Index reference
MMN44FAS007

Acoustic performance

Measured sound reduction and ISO 717-1 shifted reference curve.

View frequency-band values
Frequency (Hz)Measured R (dB)
10021.8
12523.4
16025.6
20025.4
25026.5
31528.1
40029.3
50029.9
63031.0
80031.6
100030.7
125029.0
160029.6
200031.1
250032.6
315033.5

Published acoustic test evidence does not, by itself, establish fire-door compliance. Check the relevant fire test and application evidence for the intended installation.