ACOUSTIC SYSTEM DETAILS ● WIA APPROVED SYSTEM
← Back to results

Marksman

MMN44NOR005 · Operational test

31.00 dB Rw

Rw (C; Ctr) = 31.00 (-1; -2) dB

System specification

Door core
Marksman
Leaf thickness
44 mm
Doorset configuration
SASD
Glazing
Unglazed
Frame intumescent seal
15x4 Fire Only
Frame acoustic seal
Norseal NOR 710
Meeting stile arrangement
N/A
Threshold seal
Norseal NOR 810S
Laboratory
Cambridge Acoustic Laboratory
Test report reference
24014-R01-A 
Test number
30
Index reference
MMN44NOR005

Acoustic performance

Measured sound reduction and ISO 717-1 shifted reference curve.

View frequency-band values
Frequency (Hz)Measured R (dB)
10021.6
12524.0
16026.9
20026.3
25028.1
31530.5
40031.3
50032.0
63033.0
80031.1
100028.4
125027.8
160028.2
200029.7
250031.9
315034.3

Published acoustic test evidence does not, by itself, establish fire-door compliance. Check the relevant fire test and application evidence for the intended installation.