ACOUSTIC SYSTEM DETAILS ● WIA APPROVED SYSTEM
← Back to results

Marksman

MMN44NOR006 · Operational test

31.00 dB Rw

Rw (C; Ctr) = 31.00 (-1; -2) dB

System specification

Door core
Marksman
Leaf thickness
44 mm
Doorset configuration
SADD
Glazing
Unglazed
Frame intumescent seal
15x4 Fire Only
Frame acoustic seal
Norseal NOR 710
Meeting stile arrangement
1 No. 10x4 Fire Only, 1 No. 10x4 Pyroplex 30170 (double flipper)
Threshold seal
Norseal NOR 810S
Laboratory
Cambridge Acoustic Laboratory
Test report reference
24014-R01-A 
Test number
33
Index reference
MMN44NOR006

Acoustic performance

Measured sound reduction and ISO 717-1 shifted reference curve.

View frequency-band values
Frequency (Hz)Measured R (dB)
10023.4
12526.1
16026.8
20026.6
25028.4
31529.7
40030.8
50031.7
63031.9
80030.6
100028.7
125027.5
160028.4
200029.9
250031.6
315033.8

Published acoustic test evidence does not, by itself, establish fire-door compliance. Check the relevant fire test and application evidence for the intended installation.