Marksman
MMN44NOR006 · Operational test
31.00 dB Rw
Rw (C; Ctr) = 31.00 (-1; -2) dB
System specification
- Door core
- Marksman
- Leaf thickness
- 44 mm
- Doorset configuration
- SADD
- Glazing
- Unglazed
- Frame intumescent seal
- 15x4 Fire Only
- Frame acoustic seal
- Norseal NOR 710
- Meeting stile arrangement
- 1 No. 10x4 Fire Only, 1 No. 10x4 Pyroplex 30170 (double flipper)
- Threshold seal
- Norseal NOR 810S
- Laboratory
- Cambridge Acoustic Laboratory
- Test report reference
- 24014-R01-A
- Test number
- 33
- Index reference
- MMN44NOR006
Acoustic performance
Measured sound reduction and ISO 717-1 shifted reference curve.
View frequency-band values
| Frequency (Hz) | Measured R (dB) |
|---|---|
| 100 | 23.4 |
| 125 | 26.1 |
| 160 | 26.8 |
| 200 | 26.6 |
| 250 | 28.4 |
| 315 | 29.7 |
| 400 | 30.8 |
| 500 | 31.7 |
| 630 | 31.9 |
| 800 | 30.6 |
| 1000 | 28.7 |
| 1250 | 27.5 |
| 1600 | 28.4 |
| 2000 | 29.9 |
| 2500 | 31.6 |
| 3150 | 33.8 |
Published acoustic test evidence does not, by itself, establish fire-door compliance. Check the relevant fire test and application evidence for the intended installation.