Marksman
MMN44STS005 · Operational test
31.00 dB Rw
Rw (C; Ctr) = 31.00 (-1; -2) dB
System specification
- Door core
- Marksman
- Leaf thickness
- 44 mm
- Doorset configuration
- SASD
- Glazing
- Unglazed
- Frame intumescent seal
- Sealed Tight Solutions STS1504SBS
- Frame acoustic seal
- Sealed Tight Solutions STS1009
- Meeting stile arrangement
- N/A
- Threshold seal
- Sealed Tight Solutions ST 422
- Laboratory
- Cambridge Acoustic Laboratory
- Test report reference
- 24014-R01-A
- Test number
- 14
- Index reference
- MMN44STS005
Acoustic performance
Measured sound reduction and ISO 717-1 shifted reference curve.
View frequency-band values
| Frequency (Hz) | Measured R (dB) |
|---|---|
| 100 | 20.8 |
| 125 | 22.2 |
| 160 | 26.7 |
| 200 | 26.0 |
| 250 | 27.7 |
| 315 | 30.5 |
| 400 | 31.7 |
| 500 | 32.1 |
| 630 | 32.9 |
| 800 | 31.5 |
| 1000 | 29.0 |
| 1250 | 27.9 |
| 1600 | 28.4 |
| 2000 | 30.0 |
| 2500 | 32.1 |
| 3150 | 33.7 |
Published acoustic test evidence does not, by itself, establish fire-door compliance. Check the relevant fire test and application evidence for the intended installation.