ACOUSTIC SYSTEM DETAILS ● WIA APPROVED SYSTEM
← Back to results

Marksman

MMN44LOR003 · Operational test

32.00 dB Rw

Rw (C; Ctr) = 32.00 (-1; -2) dB

System specification

Door core
Marksman
Leaf thickness
44 mm
Doorset configuration
SASD
Glazing
Glazed - 7mm Glass
Frame intumescent seal
15x4 Fire Only
Frame acoustic seal
Lorient Batwing LAS1212
Meeting stile arrangement
N/A
Threshold seal
Lorient LAS8001 SI
Laboratory
Cambridge Acoustic Laboratory
Test report reference
24014-R01-A 
Test number
22
Index reference
MMN44LOR003

Acoustic performance

Measured sound reduction and ISO 717-1 shifted reference curve.

View frequency-band values
Frequency (Hz)Measured R (dB)
10021.7
12523.5
16025.8
20024.9
25026.6
31529.5
40029.9
50030.6
63031.9
80032.9
100032.6
125032.1
160032.2
200031.9
250030.3
315029.0

Published acoustic test evidence does not, by itself, establish fire-door compliance. Check the relevant fire test and application evidence for the intended installation.