ACOUSTIC SYSTEM DETAILS ● WIA APPROVED SYSTEM
← Back to results

Marksman

MMN44LOR007 · Operational test

32.00 dB Rw

Rw (C; Ctr) = 32.00 (-1; -1) dB

System specification

Door core
Marksman
Leaf thickness
44 mm
Doorset configuration
SADD
Glazing
Unglazed
Frame intumescent seal
15x4 Fire Only
Frame acoustic seal
Lorient Batwing LAS1212
Meeting stile arrangement
1 No. 10x4 Fire Only, 1 No. 10x4 Lorient DS
Threshold seal
Lorient LAS8001 SI
Laboratory
Cambridge Acoustic Laboratory
Test report reference
24014-R01-A 
Test number
47
Index reference
MMN44LOR007

Acoustic performance

Measured sound reduction and ISO 717-1 shifted reference curve.

View frequency-band values
Frequency (Hz)Measured R (dB)
10022.5
12524.7
16026.1
20025.7
25028.2
31529.5
40030.5
50031.2
63032.5
80033.2
100032.6
125031.9
160031.4
200031.3
250030.5
315030.4

Published acoustic test evidence does not, by itself, establish fire-door compliance. Check the relevant fire test and application evidence for the intended installation.