ACOUSTIC SYSTEM DETAILS ● WIA APPROVED SYSTEM
← Back to results

Marksman

MMN44NOR007 · Operational test

32.00 dB Rw

Rw (C; Ctr) = 32.00 (-1; -1) dB

System specification

Door core
Marksman
Leaf thickness
44 mm
Doorset configuration
SADD
Glazing
Glazed - 7mm Glass
Frame intumescent seal
15x4 Fire Only
Frame acoustic seal
Norseal NOR 710
Meeting stile arrangement
1 No. 10x4 Fire Only, 1 No. 10x4 Pyroplex 30170 (double flipper)
Threshold seal
Lorient LAS8001 SI
Laboratory
Cambridge Acoustic Laboratory
Test report reference
24014-R01-A 
Test number
51
Index reference
MMN44NOR007

Acoustic performance

Measured sound reduction and ISO 717-1 shifted reference curve.

View frequency-band values
Frequency (Hz)Measured R (dB)
10022.6
12525.1
16026.2
20026.8
25028.6
31529.1
40030.5
50031.2
63033.1
80033.2
100032.7
125031.9
160031.4
200030.9
250030.9
315032.2

Published acoustic test evidence does not, by itself, establish fire-door compliance. Check the relevant fire test and application evidence for the intended installation.