ACOUSTIC SYSTEM DETAILS ● WIA APPROVED SYSTEM
← Back to results

Marksman

MMN44DIG009 · Operational test

33.00 dB Rw

Rw (C; Ctr) = 33.00 (-1; -2) dB

System specification

Door core
Marksman
Leaf thickness
44 mm
Doorset configuration
SADD
Glazing
Glazed - 7mm Glass
Frame intumescent seal
15x4 Fire Only
Frame acoustic seal
Sealmaster Delta
Meeting stile arrangement
1 No. 10x4 Fire Only, 1 No. 10x4 Therm-A-Blade
Threshold seal
Sealmaster DRP2712E
Laboratory
Cambridge Acoustic Laboratory
Test report reference
24014-R01-A 
Test number
50
Index reference
MMN44DIG009

Acoustic performance

Measured sound reduction and ISO 717-1 shifted reference curve.

View frequency-band values
Frequency (Hz)Measured R (dB)
10025.3
12526.8
16026.1
20026.7
25028.8
31529.3
40030.6
50031.2
63033.0
80033.7
100032.6
125032.1
160031.5
200031.8
250033.1
315034.1

Published acoustic test evidence does not, by itself, establish fire-door compliance. Check the relevant fire test and application evidence for the intended installation.