Trisound S3K
S3K54FAS003 · Operational test
38.00 dB Rw
Rw (C; Ctr) = 38.00 (-1; -4) dB
System specification
- Door core
- Trisound S3K
- Leaf thickness
- 54 mm
- Doorset configuration
- SASD
- Glazing
- Unglazed
- Frame intumescent seal
- 15x4 Fire Only
- Frame acoustic seal
- Fire and Acoustic Seals FAS35
- Meeting stile arrangement
- 1 No. 15x4 Fire Only, 1 No. 15x4 Lorient DS
- Threshold seal
- Fire and Acoustic Seals CCE Top Plus
- Laboratory
- Sound Research Laboratory
- Test report reference
- C/22478/T02
- Test number
- 71
- Index reference
- S3K54FAS003
Acoustic performance
Measured sound reduction and ISO 717-1 shifted reference curve.
View frequency-band values
| Frequency (Hz) | Measured R (dB) |
|---|---|
| 100 | 24.1 |
| 125 | 26.2 |
| 160 | 28.5 |
| 200 | 27.6 |
| 250 | 27.5 |
| 315 | 28.6 |
| 400 | 31.6 |
| 500 | 33.9 |
| 630 | 36.4 |
| 800 | 39.0 |
| 1000 | 40.7 |
| 1250 | 42.2 |
| 1600 | 42.2 |
| 2000 | 43.1 |
| 2500 | 43.2 |
| 3150 | 42.0 |
Published acoustic test evidence does not, by itself, establish fire-door compliance. Check the relevant fire test and application evidence for the intended installation.