ACOUSTIC SYSTEM DETAILS ● WIA APPROVED SYSTEM
← Back to results

Trisound S3K

S3K54FAS003 · Operational test

38.00 dB Rw

Rw (C; Ctr) = 38.00 (-1; -4) dB

System specification

Door core
Trisound S3K
Leaf thickness
54 mm
Doorset configuration
SASD
Glazing
Unglazed
Frame intumescent seal
15x4 Fire Only
Frame acoustic seal
Fire and Acoustic Seals FAS35
Meeting stile arrangement
1 No. 15x4 Fire Only, 1 No. 15x4 Lorient DS
Threshold seal
Fire and Acoustic Seals CCE Top Plus
Laboratory
Sound Research Laboratory
Test report reference
C/22478/T02
Test number
71
Index reference
S3K54FAS003

Acoustic performance

Measured sound reduction and ISO 717-1 shifted reference curve.

View frequency-band values
Frequency (Hz)Measured R (dB)
10024.1
12526.2
16028.5
20027.6
25027.5
31528.6
40031.6
50033.9
63036.4
80039.0
100040.7
125042.2
160042.2
200043.1
250043.2
315042.0

Published acoustic test evidence does not, by itself, establish fire-door compliance. Check the relevant fire test and application evidence for the intended installation.