ACOUSTIC SYSTEM DETAILS ● WIA APPROVED SYSTEM
← Back to results

Trisound S3K

S3K54FAS004 · Operational test

38.00 dB Rw

Rw (C; Ctr) = 38.00 (-1; -3) dB

System specification

Door core
Trisound S3K
Leaf thickness
54 mm
Doorset configuration
SASD
Glazing
Glazed - 15 Pyrostop
Frame intumescent seal
15x4 Fire Only
Frame acoustic seal
Fire and Acoustic Seals FAS35
Meeting stile arrangement
1 No. 15x4 Fire Only, 1 No. 15x4 Lorient DS
Threshold seal
Fire and Acoustic Seals CCE Top Plus
Laboratory
Sound Research Laboratory
Test report reference
C/22478/T02
Test number
73
Index reference
S3K54FAS004

Acoustic performance

Measured sound reduction and ISO 717-1 shifted reference curve.

View frequency-band values
Frequency (Hz)Measured R (dB)
10025.3
12526.4
16030.6
20031.5
25030.9
31532.0
40032.8
50033.3
63035.0
80036.8
100038.2
125039.0
160040.4
200042.0
250043.0
315044.5