ACOUSTIC SYSTEM DETAILS ● WIA APPROVED SYSTEM
← Back to results

Trisound S3K

S3K54FAS002 · Operational test

40.00 dB Rw

Rw (C; Ctr) = 40.00 (-1; -4) dB

System specification

Door core
Trisound S3K
Leaf thickness
54 mm
Doorset configuration
SASD
Glazing
Glazed - 16.8mm Opti-phon
Frame intumescent seal
Lorient 15x4 DS
Frame acoustic seal
Fire and Acoustic Seals FAS35
Meeting stile arrangement
N/A
Threshold seal
Fire and Acoustic Seals CCE Top Plus
Laboratory
Sound Research Laboratory
Test report reference
C/22478/T02
Test number
48
Index reference
S3K54FAS002

Acoustic performance

Measured sound reduction and ISO 717-1 shifted reference curve.

View frequency-band values
Frequency (Hz)Measured R (dB)
10026.6
12525.6
16026.9
20028.1
25029.2
31532.4
40034.8
50035.5
63038.3
80041.3
100041.4
125042.4
160044.0
200045.4
250046.0
315045.5

Published acoustic test evidence does not, by itself, establish fire-door compliance. Check the relevant fire test and application evidence for the intended installation.