Trisound S3K
S3K54FAS002 · Operational test
40.00 dB Rw
Rw (C; Ctr) = 40.00 (-1; -4) dB
System specification
- Door core
- Trisound S3K
- Leaf thickness
- 54 mm
- Doorset configuration
- SASD
- Glazing
- Glazed - 16.8mm Opti-phon
- Frame intumescent seal
- Lorient 15x4 DS
- Frame acoustic seal
- Fire and Acoustic Seals FAS35
- Meeting stile arrangement
- N/A
- Threshold seal
- Fire and Acoustic Seals CCE Top Plus
- Laboratory
- Sound Research Laboratory
- Test report reference
- C/22478/T02
- Test number
- 48
- Index reference
- S3K54FAS002
Acoustic performance
Measured sound reduction and ISO 717-1 shifted reference curve.
View frequency-band values
| Frequency (Hz) | Measured R (dB) |
|---|---|
| 100 | 26.6 |
| 125 | 25.6 |
| 160 | 26.9 |
| 200 | 28.1 |
| 250 | 29.2 |
| 315 | 32.4 |
| 400 | 34.8 |
| 500 | 35.5 |
| 630 | 38.3 |
| 800 | 41.3 |
| 1000 | 41.4 |
| 1250 | 42.4 |
| 1600 | 44.0 |
| 2000 | 45.4 |
| 2500 | 46.0 |
| 3150 | 45.5 |
Published acoustic test evidence does not, by itself, establish fire-door compliance. Check the relevant fire test and application evidence for the intended installation.