Trisound S3K
S3K54STS002 · Operational test
41.00 dB Rw
Rw (C; Ctr) = 41.00 (-1; -4) dB
System specification
- Door core
- Trisound S3K
- Leaf thickness
- 54 mm
- Doorset configuration
- SASD
- Glazing
- Galzed - 12mm Glass
- Frame intumescent seal
- 15x4 Fire Only
- Frame acoustic seal
- Sealed Tight Solutions STS1009
- Meeting stile arrangement
- N/A
- Threshold seal
- Sealed Tight Solutions ST422GT
- Laboratory
- Sound Research Laboratory
- Test report reference
- C/23306/T07
- Test number
- 53
- Index reference
- S3K54STS002
Acoustic performance
Measured sound reduction and ISO 717-1 shifted reference curve.
View frequency-band values
| Frequency (Hz) | Measured R (dB) |
|---|---|
| 100 | 26.0 |
| 125 | 27.8 |
| 160 | 31.0 |
| 200 | 30.0 |
| 250 | 32.0 |
| 315 | 35.9 |
| 400 | 35.5 |
| 500 | 37.0 |
| 630 | 39.9 |
| 800 | 42.7 |
| 1000 | 42.9 |
| 1250 | 41.2 |
| 1600 | 40.9 |
| 2000 | 42.2 |
| 2500 | 42.5 |
| 3150 | 42.9 |
Published acoustic test evidence does not, by itself, establish fire-door compliance. Check the relevant fire test and application evidence for the intended installation.